Reducing Overhead Corrosion through continuous analysis & online control

Story Image

The Situation

A European Refiner is aggressive in their crude selection, which poses a high degree of difficulty in controlling the overhead corrosion. This challenge demands constant attention, but due to the high degree of variability, corrosion control often struggled historically with frequent low pH excursions (pH less than 5). In response the refinery was considering upgrading the metallurgy of the overheads to address the corrosion concerns.

The automated corrosion control program improved reliability and eliminated the need for a $5M metallurgy upgrade project.

The Solution

Historically, the crude unit overheads were sampled daily for pH, chlorides, iron and ammonia. To improve corrosion performance, the refinery was interested in the 3D TRASAR™ Technology for Crude Overhead Systems (3DTCOS). If successful, the refinery could avoid a capital project worth $5M to upgrade the system to a more corrosion resistant metallurgy.

the results

Starting in Monitor Mode, the "learning phase" was catching potential upsets as changes were made manually to improve performance. Progressing to Control Mode tightened corrosion performance further. The improvements realized on pH and Fe (controlling neutralizer), grew our data collection to over 17,500 points a year. The performance gain continued with chemical control.

This step-change in performance increased unit reliability and system assurance, while real-time analysis and chemistry control enhanced crude flexibility. With a higher confidence to catch upsets, the $5M metallurgy upgrade project could be avoided.

Related Success Stories

Partnering with customers to solve their greatest challenges.

Pulp Wash Intelligence Delivers Consistently Clean Pulp

An integrated kraft mill producing 1,500 TPD in North America was looking to improve and automate its brown stock washin...

qatest013

Korean automaker reduces wastewater sludge with expert support from Nalco Water

International automaker achieves cost savings and sustainability gains through wastewater treatment program from Nalco W...

3DTCOS Improves Low PH Events

Innovative online analyzer helps identify corrosion root cause saving $6.7 Million per year....

HEAT Exchanger Reliability Management Success Story

Nalco Water Heat Optimized Maintenance Cost and Improved reliability for a Petrochemical Plant...

A Bold New Climate Commitment

Ecolab joins the Business Ambition for 1.5C, a group of global companies committed to doing their part to curb climate c...

Innovating for a Greener Paint Shop | Story

Through extensive research and rigorous field testing, we developed APEX™ Paint Detackification Technology, the first tr...

Building an Action Plan for Smart Water Management

Digital Realty was on a mission to improve its water strategy, minimize overall water use, ensure reliable performance a...

Wringing Out Big Savings for Commercial Laundries

Five leading textile service groups in Australia and New Zealand recently turned to Ecolab to help them: reduce water an...

Ecolab Large Fly Program Reduces Large Flies in Quick Service Restaurants

In many quick service restaurants, flies congregate near the dumpster and may enter the restaurant through open doors or...

Reducing Rodent Risk Helps Protect Restaurant Brand

A national restaurant chain implemented Ecolab's Rodent Ceiling Service, resulting in more than 97% of locations having ...

Maximize Machine Performance with Navigator™ and Yankee Operation Intelligence

Learn how Nalco Water’s Navigator™ Technology and Yankee Operation Intelligence helps a tissue customer improve machine ...