Cleaning Program Increases Electric Power General in a Geothermal Plant

Story Image

Situation

A Geothermal Power Plant experiment operating problem due to the chemical and biological oxidation of sulfides in the geothermal condensate. Serious rhombic sulfur fouling occurred, both in lines and fill of the cooling tower and barometric condensers, causing loss of condenser vacuum and therefore electric power generation losses in both units.

Rhombic sulfur fouling concentration amounted to more than 94%, which is highly difficult to remove online.

The first unit, with initial capacity to produce 26.8 Mw, was producing only ~19.5 Mw. When the unit was taken offline, serious sulfur fouling was found in its condenser fill.

Story Image

Solution

By laboratory tests, Nalco Water designed and developed a cleaning solution composed of emollients, wetting agents, solubilizers and highly powerful complexing agents. 

The sulfur deposits were eliminated by solubilizing their supporting salts and breaking down the sulfur macro crystals, using a highly alkaline solution developed by Nalco Water.

Story Image

Results

As a result of the chemical cleaning program recommended and advised by Nalco Water, the unit reported a three-Mw/Hr increase in electric power generation per unit once placed back in operation.

Likewise, in a joint operation of the geothermal power plant, the vacuum pumps were cleaned and repaired, and the cooling tower film type fill was changed to a hybrid type fill. This enabled the power plant to bring the unit up to nearly 27-Mw of generation, thus eliminating the derating completely.

Story Image
eROI Logo
Annual Savings
Operational Performance
980,000
Value Delivered
View definition
Energy
24.48 Millionkwh

Related Success Stories

Partnering with customers to solve their greatest challenges.

Pulp Wash Intelligence Delivers Consistently Clean Pulp

An integrated kraft mill producing 1,500 TPD in North America was looking to improve and automate its brown stock washin...

qatest013

Korean automaker reduces wastewater sludge with expert support from Nalco Water

International automaker achieves cost savings and sustainability gains through wastewater treatment program from Nalco W...

3DTCOS Improves Low PH Events

Innovative online analyzer helps identify corrosion root cause saving $6.7 Million per year....

HEAT Exchanger Reliability Management Success Story

Nalco Water Heat Optimized Maintenance Cost and Improved reliability for a Petrochemical Plant...

A Bold New Climate Commitment

Ecolab joins the Business Ambition for 1.5C, a group of global companies committed to doing their part to curb climate c...

Innovating for a Greener Paint Shop | Story

Through extensive research and rigorous field testing, we developed APEX™ Paint Detackification Technology, the first tr...

Building an Action Plan for Smart Water Management

Digital Realty was on a mission to improve its water strategy, minimize overall water use, ensure reliable performance a...

Wringing Out Big Savings for Commercial Laundries

Five leading textile service groups in Australia and New Zealand recently turned to Ecolab to help them: reduce water an...

Ecolab Large Fly Program Reduces Large Flies in Quick Service Restaurants

In many quick service restaurants, flies congregate near the dumpster and may enter the restaurant through open doors or...

Reducing Rodent Risk Helps Protect Restaurant Brand

A national restaurant chain implemented Ecolab's Rodent Ceiling Service, resulting in more than 97% of locations having ...

Maximize Machine Performance with Navigator™ and Yankee Operation Intelligence

Learn how Nalco Water’s Navigator™ Technology and Yankee Operation Intelligence helps a tissue customer improve machine ...